T3000 series is a highly reliable and accurate liquid level transducer. It can be widely used in liquid pressure and liquid level measurement, such as water, oil and other low corrosive liquids.
It features with 1Cr18Ni9Ti stainless structure, high quality oil-filled pressure sensing unit, special amplifier and V/I transducer circuit board, which make it easy to be calibrate the zero point and full scale by external program-controlled.
The transducer can be configured wearable, oil-resistant, acid and alkali resistant, high strength breathable cable according to different field using environment.
Specification
Measurement Range | 0~0.1……1mH2O, 0~1……500mH2O | |||
Overload Pressure | 1.5 times of full scales | |||
Burst Pressure | 3 times of full scales | |||
Accuracy | ±0.5%F.S, ±1%F.S | |||
Long Term Stability | Typical value: 0.1%F.S, Maximum: 0.2%F.S | |||
Working Temperature | -40°C~85°C | |||
Compensated Temperature | -10°C~70°C | |||
Medium Compatibility | All corrosive medium compatible with 1Cr18Ni9Ti and316L | |||
Electrical overview | Two- wired | Three-wired | ||
Output | 4~20mA | 0.5~4.5VDC | 0/1~5VDC | 0~10VDC |
Power Supply | 12~36VDC | 5VDC | 10~36VDC/AC | 12~36VDC/AC |
Load Resistance | (U-10)/0.02 | >100k? | ||
Insulation | >100M?@50V | |||
Electrical Connection | Waterproof cover + Two rectangular Ring + Seal ring + Sealant +Glue, Protection: IP68 | |||
Pressure Connection | G1/4 thread or Dive type | |||
Response Time | 10ms | |||
Pressure Type | Gauge pressure | |||
Electromagnetic compatibility | Electromagnetic transmit: EN50081-1/-2; Electromagnetic sensitivity: EN50082-2 | |||
Lightning-proof | Air conduction voltage 8000V, shell or cable conduction voltage 4000V; Can also be provided according to customer’s requirement |